ephy-mess

Tailor-made sensors. Worldwide.

Show product finder 

Technical information

Slot Resistance Thermometer with shrinkable tubing NWT-SH

[1] Measuring resistors 1 or 2 measuring resistors
Temperature sensor measuring wire with bifilar winding
[2] Rated resistance at 0° 100 Ω
Resistance material platinum (Pt) optionally: nickel (Ni), copper (Cu)
TEL thermometer length minus approx. 20 mm
Recommended measuring current 0.3mA … 1.0mA
Max. voltage 60V
Sensor insulation several layers of insulating preformed parts and PTFE shrinkable tubing
[3] Tolerance class according to EN 60751
[4] Mode of connection 2- // 3- // 4- conductor connection
[5] Dimensions
Thickness 2.0 mm – 8.0 mm ± 0.2 mm
Width 7.0 mm – 20 mm ± 0.2 mm
Length 75 mm – 500 mm ± 2 mm
[6] Connection line
E1 single litz wires
Sx shrinkable tubing with x single litz wires
FSLx flat band shrinkable tubing with x single litz wires
Insulation PTFE
Cross section ≥AWG 30
Shield as requested by customer
Cable end bare // tinned // wire end sheathes
[7] Cable length as requested by customer
Color code according to EN 60751 // as requested by customer
[8] Dielectric strength max. 2.5 kV / AC 50 Hz / 1 min.
[9] Measuring range -50°C … +200°C
[10] Ex-approval
IECEx Ex eb IIC
Ex ta IIIC
Ex ia IIC Gb
Ex ia IIIC Gb
ATEX II 2G Ex e IIC Gb
II 2D Ex ta IIIC Da
II 2G Ex ia IIC Gb
II 2D Ex ia IIIC Db
TR Ex ia IIC U
Ex e II U
Ex ia IIIC Db U
Ex tb IIIC Db U

Tolerance class

Unit Class AA Class A Class B Class C Class D
[Ω] ±.04 Ω / 0°C ±0.06 Ω / 0°C ±0.12 Ω / 0°C ±0.30 Ω / 0°C ±0.50 Ω / 0°C
[°C] ±0.10°C / 0°C ±0.15°C / 0°C ±0.30°C / 0°C ±0.80°C / 0°C ±1.30°C / 0°C

Example for order code / Product description

[1] [2] [3] [4] [5] [6] [7] [8] [9] [10]
NWT-SH 1 Pt100 A 3 2x8x200 E1 2000 2.5 180 Ex e
NWT-SH 2 Pt100 B 2 3x10x300 S4 5000 2 200 Ex ib

 

back

We use cookies to optimize and continuously improve our website for you. By continuing to use the website, you agree to the use of cookies. Further information on cookies can be found in our privacy statement.